Next Generation Luminaires Design Competition

Technical Requirements

The following entry categories are subject to the listed minimum efficacy requirements. Efficacies must be substantiated by independent LM-79-08 testing for the exact product submitted. Entries submitted in the listed categories below that do not meet the listed minimum efficacy requirements will not be judged.

Application Miniumum luminaire efficacy (lm/W)
Under-cabinet lighting 30 lm/W
Portable desk/task lights 30 lm/W
Recessed, surface and pendant mounted downlights 35 lm/W
Cove lighting 40 lm/W
Wall washing 30 lm/W
Street/roadway 50 lm/W
Outdoor wall packs 50 lm/W
Parking garage 50 lm/W
Outdoor pathway 25 lm/W
Outdoor step light 20 lm/W

Entries in categories not listed above are not required to meet minimum luminaire efficacy requirements by application, but LM-79-08 testing data will be carefully reviewed by judges. Energy efficiency is a strong component of the judging criteria.

All entries are subject to the following minimum color quality requirements:

    Indoor Entries:
      Allowable CCTs:  2700K - 4200K
      Allowable minimum CRI:  75
    Outoor Entries:
      Allowable CCTs:  2700K - 5500K (for consistent judging, +/- 4000K is preferred)
      Allowable minimum CRI:  50

For complete competition details see the Next Generation Luminaires 2010 Entrant Guide.